The 2-Minute Rule for Olympus Magna-Mike 8600 Thickness Gauge

Calibration: Corridor Outcome devices have to be calibrated prior to use, using the similar probe and goal that can be used for measurements. This is accomplished by getting readings without any goal, Using the focus on touching the probe (zero thickness), and at two or maybe more reference thicknesses. This permits the instrument to generate a calibration desk that plots voltage alterations compared to thickness.

Probe orientation: As the Magna-Mike 8600 actions thickness by monitoring tiny changes in the magnetic industry, its calibration process includes an automatic payment for the effects on the earth's magnetic area. Most commonly, the probe is held at a relentless orientation, vertically in the stand. Even so in scenarios in which the probe is utilized at another orientation (for instance being held horizontally), or if the orientation is shifting as in scanning the skin of a curved aspect, calibration should be updated.

Replaceable Wear Caps: Equally the conventional and chisel-type replaceable don caps are there to be certain sturdiness and increase the life of the instrument.

The Magna-Mike has an in depth file-centered alphanumeric data logger that is certainly designed to simply store and transfer thickness readings.

The probe's Corridor Result sensor actions the gap amongst the probe tip and concentrate on ball. The measurements are instantaneously exhibited on the massive color thickness Display screen as a fairly easy-to-examine digital thickness looking at.

The Magna-Mike™ 8600 Hall-influence thickness gauge takes advantage of a straightforward magnetic method for making trusted and repeatable measurements on plastic bottles, packaging, and various nonferrous components.

Probe orientation Because the Magna-Mike 8600 steps thicknesses by monitoring tiny improvements within a magnetic industry, its calibration course of action contains an automated compensation for the effects with the earth’s magnetic subject.

The Magna-Mike® 8600 is a portable thickness gauge that utilizes a straightforward magnetic approach for making trustworthy and repeatable measurements on nonferrous supplies. Operation of the Magna-Mike is quite simple. Measurements are created when its magnetic probe is held or scanned on just one facet of your test materials and a little target ball (or disk or wire) is placed on the opposite facet or dropped within a container. The probe's Corridor Impact sensor measures the distance involving the probe suggestion and target ball. The measurements are instantaneously displayed on the large colour thickness Exhibit as a straightforward-to-read through digital thickness looking at. New Capabilities • A few new resilient probe types: - Straight, Right Angle, and Low-profile Articulating • Replaceable Use Caps - Typical, Chisel suggestion, and Prolonged Have on (for 86PR-one and 86PR-2 only) • Expanded concentrate on choice - 3/sixteen and 1/4 in.

The Magna-Mike 8600 has RS-232 and USB outputs that enable the instrument to immediately deliver info to an Excel distribute sheet. The integrated WINXL interface method allows you to solitary send out or file ship thickness readings.

You should fill this kind to ask for a call-again from our customer assist supervisor with pricing and details.

Ergonomic design and style and main-edge optics outline our Clinical merchandise, generating our upright microscopes perfect for schedule daily use. From pathology to cytology, Olympus microscopes present remarkable optical performance optimized with the clinical laboratory workspace.

Wall thickness is measured by positioning a little metal goal (ball, disk, or wire) on one particular facet of the test piece and also the magnetic probe on the opposite side. The Magna-Mike precisely steps the space between the probe idea and the focus on, which corresponds for the thickness of your wall.

The probe's Corridor Result sensor actions the gap between the probe tip and target ball. The measurements are instantaneously displayed on the massive coloration thickness Display screen as a simple-to-go through digital thickness studying.

Wire targets: When utilizing the wire concentrate on, the probe tip must be positioned a minimum of 1 in. (25 mm) from the stop of your wire. The wire need to be pressed securely from the test piece at the point of measurement, due to the fact As with all other goal the Magna-Mike Olympus Magna-Mike 8600 Thickness Gauge is in fact measuring the space for the target, not the wall thickness specifically.